Philips Respironics' DreamStation Auto positive airway pressure (PAP) sleep therapy devices are designed to be as comfortable and easy to experience as sleep is intended to be. Connecting patients and care teams, DreamStation devices empower users to embrace their care with confidence, and enable care teams to practice efficient and effective patient management.
Caution: the package contains the heated humidifier and NOT heated circuit.
Connectivity options offer more monitoring choices than any leading CPAP brand with integrated Bluetooth® on every device, and offering optional Wi-Fi and cellular modems.
Performance Check simplifies in-home device evaluation and can help reduce the number of normally functioning devices that are returned for service.
EZ-Start’s automatic, personalized adjustments to CPAP pressure can help patients gradually acclimate to their prescribed level of therapy.
Daily Progress Feedback displays a simple trend of patients’ nightly use to help track progress on the path to adherence.
What is included in the basic package:
What is NOT included, but must be purchased as an accessory:
DreamStation features
• Advanced event detection
• Mask type resistance control
• Mask fit check
• Oximetry capable
• Encore patient management system with optional Adherence Profiler
• DreamMapper patient self-management system compatibility
Humidification
• Fixed, adaptive or heated tube (optional)
• Pre-heat humidifier option
• Modular design with one-piece, dishwasher-safe water chamber
Protection programs
• Flex Promise program
• Bi-level Rescue program
• "One-Touch" warranty programs
Patient driven design
A sleek, stylish, low-profile design offers the important features patients told us they wanted in a therapy device. It’s small and light, making it easy to pack for travel. It features easy-to-navigate menus, a front-facing display that can be operated while lying down or sitting up in bed as well as an easy-to-clean, one-piece humidifier water chamber.
Acclimation made easy
DreamStation includes a set of tools to help make it easy for patients starting PAP therapy and for their continued long-term use. EZ-Start can help patients gradually acclimate to therapy, while SmartRamp allows users to fall asleep to lower pressures.
Simplified device evaluation
Remote troubleshooting simplifies in-home device evaluation and can help reduce the number of normally functioning devices that are returned for service. Patients can use the easy device self-diagnostic tool to reduce the time and frustration associated with device troubleshooting.
Cost-effective connectivity options
Integrated Bluetooth® is standard on every device, and optional Wi-Fi and cellular modems provide the most comprehensive suite of connectivity options among leading CPAP brands. DreamStation's modular design makes it easy for you to choose the most cost-effective option for each patient.
Support for the long term
Built-in Bluetooth makes connectivity to the DreamMapper patient self-management tool easy. DreamMapper provides goal-setting tools, helpful videos and ongoing feedback to keep patients motivated and engaged. Patients can get the help they need fast, without having to use your staff’s time to resolve.
Wake up to progress
Each morning patients are greeted with a summary of their progress to motivate them to stick with their therapy. The display shows a simple trend of their nightly hours of use, followed by a summary of the last 30 days of “good nights” that have more than 4 hours of use.
Connect to the care team
Connection to powerful Encore Anywhere patient compliance management software provides a range of tools to monitor and manage your patients. Adherence Profiler is an optional, intuitive tool that helps you focus your staff’s time on the patients with the greatest likelihood of success.
Scarica la scheda tecnica da presentare al tuo medico
Auto CPAP features
Specifications
Pressure range | 4 to 20 cm H2O |
Flex pressure relief | 0 to 3 |
Ramp time | 0 to 45 min (5-minute increments) |
Starting ramp pressure | 4 cm H2O to CPAP Pressure (CPAP); 4cm H2O to Min Pressure (Auto CPAP) |
Humidification | Heated humidification: Fixed, Adaptive, Heated Tube modes; Heated Tube (optional) |
Data storage capacity (minimum) | SD card: > 1 year On- board: <6 months |
Altitude compensation | Automatic |
Filters | Reusable pollen; disposable ultra-fine |
Device controls | LCD, control dial/push button |
Warranty | 2 years |
Dimensions | 15.7x19.3x8.4cm (w/o humidifier) 29.7x19.3x8.4cm (w/ humidifier) |
Weight | 1.33kg/2.94lbs (w/o humidifier) 1.98kg/4.37lbs (w/humidifier) Incl. power supply |
Electrical requirements | 100 – 240 VAC, 50/60 Hz, 2.0- 1.0 A |
DreamStation CPAP | DreamStation CPAP Pro | DreamStation Auto CPAP | DreamStation BiPAP Pro | DreamStation Auto BiPAP | |
Modes | Fixed CPAP | Fixed CPAP CPAP-Check | Fixed CPAP CPAP-Check Auto-CPAP | Fixed CPAP Fixed BiPAP | Fixed CPAP Fixed BiPAP Auto-BiPAP |
Features | n/a | EZ-Start Auto-Trial | EZ-Start Auto-Trial Opti-Start | EZ-Start | EZ-Start |
Pressure Range | 4 to 20 cm H₂O | 4 to 20 cm H₂O | 4 to 20 cm H₂O | 4 to 25 cm H₂O | 4 to 25 cm H₂O |
Flex Comfort | C-Flex | C-Flex C-Flex+ | C-Flex C-Flex+ A-Flex | C-Flex Bi-Flex | C-Flex Bi-Flex |
Humidification Modes (3) | Fixed Adaptive Heated Tube | Fixed Adaptive Heated Tube | Fixed Adaptive Heated Tube | Fixed Adaptive Heated Tube | Fixed Adaptive Heated Tube |
Mask Type Resistance Control | Standard | Standard | Standard | Standard | Standard |
Ramp (5-45 minutes) | Standard SmartRamp | Standard SmartRamp | Standard SmartRamp | Standard SmartRamp | Standard SmartRamp |
Altitude Compensation | Automatic | Automatic | Automatic | Automatic | Automatic |
Advanced Event Detection | n/a | Standard | Standard | Standard | Standard |
Flow Waveforms | n/a | Standard | Standard | Standard | Standard |
Modem Compatibility | Standard (optional Cellular Modem or Wi-Fi Accessory) | Standard (optional Cellular Modem or Wi-Fi Accessory) | Standard (optional Cellular Modem or Wi-Fi Accessory) | Standard (optional Cellular Modem or Wi-Fi Accessory) | Standard (optional Cellular Modem or Wi-Fi Accessory) |
Built-in Bluetooth Connectivity | Standard | Standard | Standard | Standard | Standard |
DreamMapper Compatibility | Standard (by mobileapp or web) | Standard (by mobileapp or web) | >Standard (by mobileapp or web) | Standard (by mobileapp or web) | Standard (by mobileapp or web) |
Oximetry Compatibility | Standard (optional Nonin accessories) | Standard (optional Nonin accessories) | Standard (optional Nonin accessories) | Standard (optional Nonin accessories) | Standard (optional Nonin accessories) |
Check Mask Fit feature | n/a | Standard | Standard | n/a | n/a |
Performance Check | Standard | Standard | Standard | Standard | Standard |
Cleaning the Device
Warning: To avoid electrical shock, always unplug the power cord from the wall outlet before cleaning the device.
DO NOT immerse the device in any fluids.
Cleaning or Replacing the Filters
Under normal usage, you should clean the reusable blue pollen filter at least once every two weeks and replace it with a new one every six months. The light-blue ultra-fine filter is disposable and should be replaced after 30 nights of use or sooner if it appears dirty. DO NOT clean the ultra-fine filter.
Caution: Dirty inlet filters may cause high operating temperatures that may affect device performance. Regularly examine the inlet filters as needed for integrity and cleanliness.
This device has an automatic air filter reminder. Every 30 days, the device will display a message reminding you to check your filters and replace them as directed.
Note: This message is a reminder only. The device does not detect the performance of the filters nor does it recognize when a filter has been cleaned or replaced.
Caution: Never install a wet filter into the device. You must ensure sufficient drying time for the cleaned filter.
Cleaning the Tubing
Clean the flexible tubing before first use and daily. Disconnect the flexible tubing from the device. For the 15 or 22 mm flexible tubing, gently wash the tubing in a solution of warm water and a mild detergent. Rinse thoroughly. Air dry. Inspect the tubing for damage or wear. Discard and replace if necessary.
Note: Refer to the humidifier manual for the instructions on how to clean the heated tube.
Service
The device does not require routine servicing.
Warning: If you notice any unexplained changes in the performance of this device, if it is making unusual or harsh sounds, if it has been dropped or mishandled, if water is spilled into the enclosure, or if the enclosure is broken, disconnect the power cord and discontinue use. Contact your home care provider.