Auto CPAP DreamStation + Humidifier, Bluetooth & Wi-Fi - Philips Respironics

Philips Respironics' DreamStation Auto positive airway pressure (PAP) sleep therapy devices are designed to be as comfortable and easy to experience as sleep is intended to be. Connecting patients and care teams, DreamStation devices empower users to embrace their care with confidence, and enable care teams to practice efficient and effective patient management. 

Caution: the package contains the heated humidifier and NOT heated circuit. 

More details

202110200009
New product
 
More info

Connectivity options offer more monitoring choices than any leading CPAP brand with integrated Bluetooth® on every device, and offering optional Wi-Fi and cellular modems.

Performance Check simplifies in-home device evaluation and can help reduce the number of normally functioning devices that are returned for service.

EZ-Start’s automatic, personalized adjustments to CPAP pressure can help patients gradually acclimate to their prescribed level of therapy.

Daily Progress Feedback displays a simple trend of patients’ nightly use to help track progress on the path to adherence.

What is included in the basic package:

  • Device
  • Heated humidifier
  • Wi-Fi module
  • Bluetooth module
  • Carrying case
  • Non-heated tube
  • Power supply
  • Power cord
  • Replacement filter
  • Pollen filter
  • User manual
  • Clinical manual
  • Humidifier manual
  • Accessories manual
  • SD card

What is NOT included, but must be purchased as an accessory:

  • Heated tube
  • Disposable filters, AFTER the first
  • Reusable filters, AFTER the first
  • Alternative solutions for the power supply

DreamStation features
• Advanced event detection
• Mask type resistance control
• Mask fit check
• Oximetry capable
• Encore patient management system with optional Adherence Profiler
• DreamMapper patient self-management system compatibility

Humidification
• Fixed, adaptive or heated tube (optional)
• Pre-heat humidifier option
• Modular design with one-piece, dishwasher-safe water chamber

Protection programs
• Flex Promise program
• Bi-level Rescue program
• "One-Touch" warranty programs

Patient driven design

A sleek, stylish, low-profile design offers the important features patients told us they wanted in a therapy device. It’s small and light, making it easy to pack for travel. It features easy-to-navigate menus, a front-facing display that can be operated while lying down or sitting up in bed as well as an easy-to-clean, one-piece humidifier water chamber.

Acclimation made easy

DreamStation includes a set of tools to help make it easy for patients starting PAP therapy and for their continued long-term use. EZ-Start can help patients gradually acclimate to therapy, while SmartRamp allows users to fall asleep to lower pressures.

Simplified device evaluation

Remote troubleshooting simplifies in-home device evaluation and can help reduce the number of normally functioning devices that are returned for service. Patients can use the easy device self-diagnostic tool to reduce the time and frustration associated with device troubleshooting.

Cost-effective connectivity options

Integrated Bluetooth® is standard on every device, and optional Wi-Fi and cellular modems provide the most comprehensive suite of connectivity options among leading CPAP brands. DreamStation's modular design makes it easy for you to choose the most cost-effective option for each patient.

Support for the long term

Built-in Bluetooth makes connectivity to the DreamMapper patient self-management tool easy. DreamMapper provides goal-setting tools, helpful videos and ongoing feedback to keep patients motivated and engaged. Patients can get the help they need fast, without having to use your staff’s time to resolve.

Wake up to progress

Each morning patients are greeted with a summary of their progress to motivate them to stick with their therapy. The display shows a simple trend of their nightly hours of use, followed by a summary of the last 30 days of “good nights” that have more than 4 hours of use.

Connect to the care team

Connection to powerful Encore Anywhere patient compliance management software provides a range of tools to monitor and manage your patients. Adherence Profiler is an optional, intuitive tool that helps you focus your staff’s time on the patients with the greatest likelihood of success.

Write a review

Auto CPAP DreamStation + Humidifier, Bluetooth & Wi-Fi - Philips Respironics

Philips Respironics' DreamStation Auto positive airway pressure (PAP) sleep therapy devices are designed to be as comfortable and easy to experience as sleep is intended to be. Connecting patients and care teams, DreamStation devices empower users to embrace their care with confidence, and enable care teams to practice efficient and effective patient management. 

Caution: the package contains the heated humidifier and NOT heated circuit. 

Write a review

 
Data sheet

Scarica la scheda tecnica da presentare al tuo medico

Auto CPAP features

  • C-Flex, C-Flex+, A-Flex
  • SmartRamp
  • EZ-Start
  • CPAP-Check
  • Auto-Trial 
  • Opti-Start
  • Digital AutoTrak
  • Advanced event detection
  • Waveform data
  • Standard integrated Bluetooth

Specifications

Pressure range4 to 20 cm H2O
Flex pressure relief0 to 3
Ramp time0 to 45 min (5-minute increments)
Starting ramp pressure4 cm H2O to CPAP Pressure (CPAP); 4cm H2O to Min Pressure (Auto CPAP)
HumidificationHeated humidification: Fixed, Adaptive, Heated Tube modes; Heated Tube (optional)
Data storage capacity (minimum)SD card: > 1 year On- board: <6 months
Altitude compensationAutomatic
FiltersReusable pollen; disposable ultra-fine
Device controlsLCD, control dial/push button
Warranty2 years
Dimensions15.7x19.3x8.4cm (w/o humidifier)
29.7x19.3x8.4cm (w/ humidifier)
Weight1.33kg/2.94lbs (w/o humidifier)
1.98kg/4.37lbs (w/humidifier)
Incl. power supply
Electrical requirements100 – 240 VAC, 50/60 Hz, 2.0- 1.0 A
 
Therapy Device Configuration
DreamStation CPAPDreamStation CPAP ProDreamStation Auto CPAPDreamStation BiPAP ProDreamStation Auto BiPAP
ModesFixed CPAP

Fixed CPAP

CPAP-Check

Fixed CPAP

CPAP-Check

Auto-CPAP

Fixed CPAP

Fixed BiPAP

Fixed CPAP

Fixed BiPAP

Auto-BiPAP

Featuresn/a

EZ-Start

Auto-Trial

EZ-Start

Auto-Trial

Opti-Start

EZ-StartEZ-Start
Pressure Range4 to 20 cm H₂O4 to 20 cm H₂O4 to 20 cm H₂O4 to 25 cm H₂O4 to 25 cm H₂O
Flex ComfortC-Flex

C-Flex

C-Flex+

C-Flex

C-Flex+

A-Flex

C-Flex

Bi-Flex

C-Flex

Bi-Flex

Humidification Modes (3)

Fixed

Adaptive

Heated Tube

Fixed

Adaptive

Heated Tube

Fixed

Adaptive

Heated Tube

Fixed

Adaptive

Heated Tube

Fixed

Adaptive

Heated Tube

Mask Type Resistance ControlStandardStandardStandardStandardStandard
Ramp (5-45 minutes)

Standard

SmartRamp

Standard

SmartRamp

Standard

SmartRamp

Standard

SmartRamp

Standard

SmartRamp

Altitude CompensationAutomaticAutomaticAutomaticAutomaticAutomatic
Advanced Event Detectionn/aStandardStandardStandardStandard
Flow Waveformsn/aStandardStandardStandardStandard
Modem CompatibilityStandard (optional Cellular Modem or Wi-Fi Accessory)Standard (optional Cellular Modem or Wi-Fi Accessory)Standard (optional Cellular Modem or Wi-Fi Accessory)Standard (optional Cellular Modem or Wi-Fi Accessory)Standard (optional Cellular Modem or Wi-Fi Accessory)
Built-in Bluetooth ConnectivityStandardStandardStandardStandardStandard
DreamMapper CompatibilityStandard (by mobileapp or web)Standard (by mobileapp or web)>Standard (by mobileapp or web)Standard (by mobileapp or web)Standard (by mobileapp or web)
Oximetry CompatibilityStandard (optional Nonin accessories)Standard (optional Nonin accessories)Standard (optional Nonin accessories)Standard (optional Nonin accessories)Standard (optional Nonin accessories)
Check Mask Fit featuren/aStandardStandardn/an/a
Performance CheckStandardStandardStandardStandardStandard

 
Maintenance

Cleaning the Device

Warning: To avoid electrical shock, always unplug the power cord from the wall outlet before cleaning the device.
DO NOT immerse the device in any fluids.

  1. Unplug the device, and wipe the outside of the device with a cloth slightly dampened with water and a mild detergent. Let the device dry completely before plugging in the power cord.
  2. Inspect the device and all circuit parts for damage after cleaning. Replace any damaged parts.

Cleaning or Replacing the Filters

Under normal usage, you should clean the reusable blue pollen filter at least once every two weeks and replace it with a new one every six months. The light-blue ultra-fine filter is disposable and should be replaced after 30 nights of use or sooner if it appears dirty. DO NOT clean the ultra-fine filter.
Caution: Dirty inlet filters may cause high operating temperatures that may affect device performance. Regularly examine the inlet filters as needed for integrity and cleanliness.
This device has an automatic air filter reminder. Every 30 days, the device will display a message reminding you to check your filters and replace them as directed.
Note: This message is a reminder only. The device does not detect the performance of the filters nor does it recognize when a filter has been cleaned or replaced.

  1. If the device is operating, stop the airflow. Disconnect the device from the power source.
  2. Remove the filter(s) from the device. Refer to the “Installing/Replacing the Air Filters” section of the manual.
  3. Examine the filter(s) for cleanliness and integrity.
  4. To clean the reusable blue pollen filter, first detach the light-blue ultra-fine filter if applicable, and set aside or dispose of as needed. Then take the reusable filter to the sink, turn it upside down, and run warm tap water through the white filter media to rinse away any debris. Next, lightly shake the filter to remove as much water as possible. Allow the filter to air dry completely before reinstalling it. If the reusable blue pollen filter is torn, replace it. (Only Philips Respironics-supplied filters should be used as replacement filters.)
  5. If the light-blue ultra-fine filter is dirty or torn, replace it.
  6. Reinstall the filters. Refer to the "Installing/Replacing the Air Filters" section of the manual.

Caution: Never install a wet filter into the device. You must ensure sufficient drying time for the cleaned filter.

Cleaning the Tubing

Clean the flexible tubing before first use and daily. Disconnect the flexible tubing from the device. For the 15 or 22 mm flexible tubing, gently wash the tubing in a solution of warm water and a mild detergent. Rinse thoroughly. Air dry. Inspect the tubing for damage or wear. Discard and replace if necessary.
Note: Refer to the humidifier manual for the instructions on how to clean the heated tube.

Service

The device does not require routine servicing.
Warning: If you notice any unexplained changes in the performance of this device, if it is making unusual or harsh sounds, if it has been dropped or mishandled, if water is spilled into the enclosure, or if the enclosure is broken, disconnect the power cord and discontinue use. Contact your home care provider.

12 other products in the same category: